SiENBE04-512A Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
Removal Procedure 205
3
Remove the heat
exchanger thermistor.
Be careful not to lose the
thermistor retaining spring.
Align the thermistor with the
end of the retaining spring.
4
Disconnect the
thermistor assembly
(for outdoor air, heat
exchanger, discharge
pipe) connector [S90].
Step Procedure Points
Thermistor
retaining spring
Heat exchanger
thermistor
(R4493)
[S90]
For discharge
pipe
For outdoor air
For heat exchanger
(R4494)
SiENBE04-512A.book Page 205 Friday, October 5, 2007 1:49 PM