EasyManuals Logo

Daikin FTXG25CVMAW Service Manual

Daikin FTXG25CVMAW
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
Si04-402A Main Functions
Function and Control 23
1.7 NIGHT SET Mode
When the OFF timer is set, the NIGHT SET circuit automatically activates.
The NIGHT SET circuit maintains the airflow setting made by users.
NIGHT SET
Circuit
The NIGHT SET circuit continues heating or cooling the room at the set temperature for the first
one hour, then automatically lowers the temperature setting slightly in the case of cooling, or
raises it slightly in the case of heating, for economical operations. This prevents excessive
heating in winter and excessive cooling in summer to ensure comfortable sleeping conditions,
and also conserves electricity.
Cooling Operation
Heating Operation

Table of Contents

Other manuals for Daikin FTXG25CVMAW

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTXG25CVMAW and is the answer not in the manual?

Daikin FTXG25CVMAW Specifications

General IconGeneral
BrandDaikin
ModelFTXG25CVMAW
CategoryAir Conditioner
LanguageEnglish

Related product manuals