6■English
2. Drain work
(only for heat pump models)
• Ifthedrainportiscoveredbyamountingbaseoroor
surface, place additional foot bases of at least 1-1/4
inch(30mm)inheightundertheoutdoorunit’sfeet.
• In cold areas, do not use a drain socket, drain
caps (1,2) and a drain hose with the outdoor unit.
(Otherwise, the drain water may freeze, impairing
heating performance.)
1) Attach
C
drain cap (1) and
D
drain cap (2).
2) Attach
B
drain socket.
3. Flaring the pipe end
1) Cut the pipe end with a pipe cutter.
2) Remove burrs with the cut surface facing
downward so that the chips do not enter the pipe.
3) Putthearenutonthepipe.
4) Flare the pipe.
5) Checkthatthearingisproperlymade.
Check
Flare’s inner
surface must
be flaw-free.
The pipe end must
be evenly flared in
a perfect circle.
Make sure that the
flare nut is fitted.
Set exactly at the position shown below.
Flaring
A
Die
A
0-0.020 inch
(0-0.5mm)
Clutch-type
Flare tool for R410A
0.039-0.059 inch
(1.0-1.5mm)
Clutch-type (Rigid-type)
0.059-0.079 inch
(1.5-2.0mm)
Wing-nut type (Imperial-type)
Conventional flare tool
Cut exactly at
right angles.
Remove burrs.
WARNING
• Donotusemineraloilonaredpart.
• Prevent mineral oil from getting into the system as this would reduce the lifetime of the units.
• Never use piping which has been used for previous installations. Only use parts which are delivered with the unit.
• NeverinstalladriertothisR410Aunitinordertoguaranteeitslifetime.
• The drying material may dissolve and damage the system.
• Incompletearingmaycauserefrigerantgasleakage.
4. Refrigerant piping
CAUTION
• Usethearenutxedtothemainunit.(Thisistopreventcrackingofthearenutasaresultofdeteriorationovertime.)
• Topreventgasleakage,applyrefrigerationoilonlytotheinnersurfaceoftheare.(UserefrigerationoilforR410A.)
• Useatorquewrenchwhentighteningthearenutstopreventdamagetothearenutsandgasleakage.
• Alignthecentersofbotharesandtightenthearenuts3or4turnsbyhand.Thentightenthemfullywithaspanneranda
torque wrench.
Do not apply refrigeration
oil to the outer surface.
Flare nut
Apply refrigeration oil to
the inner surface of the
flare.
Do not apply refrigeration oil to
the flare nut to avoid tightening
with excessive torque.
Apply oil
Flare nut tightening torque
Gas side
3/8 inch (9.5mm) 1/2 inch(12.7mm)
24-1/8 – 29-1/2ft • Ibf
(32.7-39.9N • m)
36-1/2 – 44-1/2ft • lbf
(49.5-60.3N • m)
5/8 inch(15.9mm)
45-5/8 – 55-5/8ft • lbf
(61.8-75.4N • m)
10-1/2 – 12-3/4ft • lbf
(14.2-17.2 N • m)
Liquid side
1/4 inch (6.4mm)
Service port cap tightening torque
8 – 10-7/8ft • lbf (10.8-14.7N • m)
Width across flats
11/16 inch(17mm)
(14.2-17.2N • m)
10-1/2 – 12-5/8ft • lbf
3/4 inch(19mm)
(17.1-20.9N • m)
12-5/8 – 15-3/8ft • lbf
7/8 inch(22mm)
(21.6-27.4N • m)
16 – 20-1/4ft • lbf
1-1/16 inch(27mm)
(48-59.8N • m)
35-3/8 – 44-1/8ft • lbf
Valve cap
tightening torque
Bottom frame
Drain cap
Pinch the bottom
frame in.
Drain cap (1)
Drain cap (1)
Air outlet side
C
C
Drain cap (2)
D
Drain
socket
B
Drain cap (1)
Drain cap (2)
D
Drain cap (2)
Air outlet side
B
Drain
socket
C
D
09/12 class 18/24 class
Bottom frame
Drain socket
Hose (available commercially,
inner dia. 5/8 ” (16mm))
B
English