4 Wiring
1)Asshownintheillustration,insertthewiresincludingthegroundwireintotheconduitandsecurethemwithlocknutonto
theconduitmountingplate.
2)Stripwireends(3/4inch(20mm)).
3)Matchwirecolourswithterminalnumbersontheterminalblockofindoorandoutdoorunitandrmlysecurethewiresin
thecorrespondingterminalswithscrews.
4)Connectthegroundwiretothecorrespondingterminals.
5)Pullthewireslightlytomakesuretheyaresecurelyconnected.
6)Whileclosetheservicelid,shapethewiressothattheservicelidtssecurely,thenclosetheservicelid.
1 2 3
Outdoor unit
1 2 3
Terminal block
Electrical wiring box
Wire retainer
Use the specified wire type.
Shape wires so that the
service lid fits securely.
Use AWG16 if the connection wire
length is less than 33ft (10m), or
AWG14 if it is 33ft (10m) or more.
Firmly fix the wires with the terminal screws.
1
2
3
Indoor
unit
Firmly fix the wires with
the terminal screws.
Back
Lock nut
Conduit mounting plate
Conduit
L
1
L
2
WARNING
• Donotusetappedwires,extensioncords,orstarburstconnections,astheymaycauseoverheating,electricalshock,orre.
• Donotuselocallypurchasedelectricalpartsinsidetheproduct.(Donotbranchthepowerforthedrainpump,etc.,fromthe
terminalblock.)Doingsomaycauseelectricshockorre.
• Donotconnectthepowerwiretotheindoorunit.Doingsomaycauseelectricshockorre.
5 Drain piping
1)Connectthedrainhose,asdescribedontheright.
2)Removetheairltersandpoursomewaterintothedrainpantocheckthe
waterowssmoothly.
3)Ifdrainhoseextensionorembeddeddrainpipingisrequired,useappropriate
partsthatmatchthehosefrontend.
4)Whenextendingthedrainhose,useacommerciallyavailable
extensionhosewithaninnerdiameterof5/8inch(16mm).
Besuretothermallyinsulatetheindoorsectionofthe
extensionhose.
Indoor unit
drain hose
Extension drain hose
Heat insulation tube
(field supply)
φ5/8”(φ16mm)
Drain hose supplied
with the indoor unit
φ5/8”(φ16mm)
Figure of hose front end
φ5/8”(φ16mm)
The drain hose should
be inclined downward.
No trap is permitted.
Do not put the end
of the hose in water.
English