Indoor Unit Installation
1 Installing the mounting plate
• Themountingplateshouldbeinstalledonawallwhichcansupporttheweightoftheindoorunit.
1)Temporarilysecurethemountingplatetothewall,makesurethatthepaneliscompletelylevel,andmarkthedrilling
pointsonthewall.
2)Securethemountingplatetothewallwithscrews.
Recommended mounting plate retention spots and dimensions
30-5/16 (770)
Place the pipe port cover
in this pocket.
Gas pipe end
Through-the-wall
hole φ2-9/16 (65)
Recommended mounting plate
retention spots (7 spots in all)
Place a leveler
on these tabs.
1-3/4 (44.5)
1-3/4 (44.5)
1-7/8 (48)
13-1/4 (337)
11-1/4 (285)
6-11/16 (170)
1-7/8 (48)
1-15/16
(50)
6-11/16
(170)
4-5/8 (116.5)
4-5/8 (117)
13-1/4 (337)
8-3/8 (213)
9-5/16 (237)
Drain hose position
Liquid pipe end
39 (990)
unit: inch (mm)
Gas pipe end
Through-the-wall
hole φ3-1/8 (80)
1-3/4 (44.5)
1-3/4 (44.5)
2-3/8 (60)
17-5/8 (447)
17-1/8 (435)
11-5/8 (295)
6-3/4 (171.5)
1-7/8 (48)
2-3/8 (60)
6-3/4 (171.5)
5 (126.5)
4-5/8 (117)
Drain hose position
Liquid pipe end
Use a tape measure
as shown.
Position the end of
the tape measure at .
13-1/8 (333)
Place a leveler
on these tabs.
Recommended mounting plate
retention spots (7 spots in all)
The removed pipe
port cover can be
kept in the mounting
plate pocket.
Mounting
plate
Removed pipe
port cover
A
09/12 class
18/24 class
01_EN_3P379970-1.indd 5 10/17/2014 12:57:23 PM