English
12
■
To change the temperature setting
Press .
•ThedisplayeditemsontheLCDwillchangewhenevereitheroneofthebuttonsis
pressed.
COOLoperation HEAToperation AUTOoperation DRYorFANoperation
18-32°C 10-30°C 18-30°C
Thetemperaturesettingis
notvariable.
Press
toraisethetemperatureandpress tolowerthe
temperature.
■
Operating conditions
■
Recommended temperature setting
• Forcooling:26-28°C
• Forheating:20-24°C
■
Tips for saving energy
• Becarefulnottocool(heat)theroomtoomuch.
Keepingthetemperaturesettingatamoderatelevelhelpssaveenergy.
• Coverwindowswithablindoracurtain.
Blockingsunlightandairfromoutdoorsincreasesthecooling(heating)effect.
• Cloggedairlterscauseinefcientoperationandwasteenergy.Cleanthemonceinaboutevery2weeks.
■
Notes on the operating conditions
• Theairconditioneralwaysconsumesasmallamountofelectricityevenwhileitisnotoperating.
• Ifyouarenotgoingtousetheairconditionerforalongperiod,forexampleinspringorautumn,turnthebreakeroff.
• Usetheairconditionerinthefollowingconditions.
MODE Operatingconditions Ifoperationiscontinuedoutofthisrange
COOL
Outdoortemperature:<2MXS>10-46°C
<3/4/5MXS>–10-46°C
<RXS>–10-46°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
•Asafetydevicemayworktostoptheoperation.
(Inmultisystem,itmayworktostoptheoperationofthe
outdoorunitonly.)
•Condensationmayoccurontheindoorunitanddrip.
HEAT
Outdoortemperature:<2/3/4/5MXS>–15-24°C
<RXS>–15-24°C
Indoortemperature:10-30°C
•Asafetydevicemayworktostoptheoperation.
DRY
Outdoortemperature:<2MXS>10-46°C
<3/4/5MXS>–10-46°C
<RXS>–10-46°C
Indoortemperature:18-32°C
Indoorhumidity:80%max.
•Asafetydevicemayworktostoptheoperation.
•Condensationmayoccurontheindoorunitanddrip.
• Operationoutsidethishumidityortemperaturerangemaycauseasafetydevicetodisablethesystem.