41
Troubleshooting
LED ON OUTDOOR UNIT PCB
3MXS, 4MXS, 5MXS series
GREEN RED
MICROCOMPUTER
NORMAL
MALFUNCTION
DETECTION
LED-A LED1 LED2 LED3 LED4 LED5 DIAGNOSIS
●●●●●
NORMAL CHECKINDOORUNIT
HIGHPRESSUREPROTECTORWORKEDORFREEZE-UPIN
OPERATINGUNITORSTAND-BYUNIT
*OVERLOADRELAYWORKEDORHIGHDISCHARGEPIPE
TEMPERATURE
FAULTYCOMPRESSORSTART
INPUTOVERCURRENT
●●●
*THERMISTORORCTABNORMALITY
HIGHTEMPERATURESWITCHBOX
●●●
HIGHTEMPERATUREAT INVERTERCIRCUITHEATSINK
●● ●●
*OUTPUTOVERCURRENT
●●
*REFRIGERANTSHORTAGE
●●
LOWVOLTAGETOMAINCIRCUITORMOMENTARYVOLTAGE
LOSS
●●●●
REVERSINGSOLENOIDVALVESWITCHINGFAILURE
FANMOTORFAU LT
−−−−
[NOTE1]
−−−−
POWERSUPPLYFAU LTOR[NOTE2]
NOTE:TheLED5isonlyavailableinthe5Mseries.
GREEN NORMALLYFLASHING
RED NORMALLYOFF
ON
FLASHING
OFF
IRRELEVANT
LED ON OUTDOOR UNIT PCB
2MXS series
GREEN
MICROCOMPUTERNORMAL
LED-A DIAGNOSIS
NORMAL CHECKINDOORUNIT
[NOTE1]
POWERSUPPLYFAU LTOR[NOTE2]
GREEN NORMALLYFLASHING
ON
FLASHING
OFF
NOTE
• Tur n thepoweroffandthenonagain.IftheLEDdisplayrecurs,theoutdoorunitPCBisfaulty.
• Diagnosismarked
*Donotapplytosomecases.Fordetails,refertotheserviceguide.