ESIE17-19C | Part 5. Appendix 5.1. Field setting
Optimized Heating 4
19/08/19 | Version 1.1 Page 109
5.1.3.3. Set target temperature in heating (DFu4)
T
set
= T
R/C,set
+ DFu4
T
set
= system set temperature
T
R/C,set
= remocon set temperature
DFu4= offset
5.1.3.3.1 Remote controller ARC466A55
Figure 5-5: How to adjust target set temperature in heating operation - Remote controller: ARC466A55
Temp Temp
MODE SC
MODE
MODE
01
MODE
Temp
Temp
2 34
Select
“SU”
Select “7”
DISPLAY NORMAL
AFTER 60 sec
Display
Select
Send signal to indoor unit
Adjust target set temperature
0: -2.0°C
1: -1.0°C
2: ±0 (factory setting)
3: +1.0°C
4: +2.0°C

Table of Contents