EasyManua.ls Logo

Daikin FTXTA30AW - Page 80

Daikin FTXTA30AW
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ESIE17-19C | Part 3. Repair 3.3. Unit specific repair procedures
Page 80 19/08/19 | Version 1.1
Optimized Heating 4
Figure 3-15: Removing the switch box
Installation
1. Proceed in reverse order.
1. Insulation 6. Wire clamp
2. Main PCB 7. Screw
3. Electrical power wiring 8. Right side plate assembly
4. Wire terminals 9. Cable tie
5. Screw 10. Switch box
8
3
6
5
7
4
1
102
9

Table of Contents