ESIE17-19C | Part 3. Repair 3.3. Unit specific repair procedures
Page 96 19/08/19 | Version 1.1
Optimized Heating 4
1. Attach new heat conductive paste (2) before attaching the heat sink (1) to the power electronics.
Figure 3-27: Apply heat conductive paste
2. Proceed in reverse order.
CAUTION
Make sure to apply enough heat conductive paste.
1. Heat sink 2. Apply heat conductive paste