82 Removal Procedure
1.9 Exchange of Drain Hose
Procedure Warning Be sure to wait 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1
Remove the fixing
screw on the right side
and remove the drain
hose.
To prevent water leakage,
make sure to mount the
fixing screw as it was.
2
Remove the drain cap
located at the left side.
Use a 4mm Allen wrench.
(R8631)
Drain hose
Fixing screw
(R8632)
Drain cap
(R8633)