Functions EDUS041016
4 Room Air Conditioners J-Series
2. Functions
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Category Functions
FTKN09/12JEVJU
RKN09/12JEVJU
FTXN09/12JEVJU
RXN09/12JEVJU
Basic
Function
Inverter (with Inverter Power Control) Health &
Clean
Air-Purifying Filter
Operation Limit for Cooling (°FDB)
50~
114.8
50~
114.8
Photocatalytic Deodorizing Filter
Operation Limit for Heating (°FWB) 5~68
Air-Purifying Filter with Photocatalytic
Deodorizing Function
——
PAM Control 
Titanium Apatite Photocatalytic
Air-Purifying Filter

Compressor Oval Scroll Compressor Air Filter (Prefilter) 
Swing Compressor  Wipe-clean Flat Panel 
Rotary Compressor Washable Grille
Reluctance DC Motor  Filter Cleaning Indicator
Comfortable
Airflow
Power-Airflow Louver (Horizontal Blade)
 Good-Sleep Cooling Operation
Power-Airflow Dual Louvers Timer 24-Hour ON/OFF Timer 
Power-Airflow Diffuser NIGHT SET Mode 
Wide-Angle Fins (Vertical Blades) Worry Free
“Reliability &
Durability”
Auto-Restart (after Power Failure) 
Vertical Auto-Swing (Up and Down)  Self-Diagnosis (Digital, LED) Display 
Horizontal Auto-Swing (Right and Left) Wiring Error Check
3-D Airflow
Anti-Corrosion Treatment of Outdoor
Heat Exchanger

COMFORT AIRFLOW Operation 
Flexibility Multi-Split / Split Type Compatible
Indoor Unit
——
Comfort
Control
Auto Fan Speed  Flexible Voltage Correspondence
Indoor Unit Quiet Operation  High Ceiling Application
NIGHT QUIET Mode (Automatic) Chargeless 32.8ft 32.8ft
Outdoor Unit Quiet Operation (Manual) Either Side Drain (Right or Left) 
INTELLIGENT EYE Operation Power Selection
Quick Warming Function
Remote
Control
5-Rooms Centralized Controller
(Option)
——
Hot-Start Function
Remote Control Adaptor
(Normal Open-Pulse Contact) (Option)
——
Automatic Defrosting
Remote Control Adaptor
(Normal Open Contact) (Option)
——
Operation Automatic Operation DIII-NET Compatible (Adaptor) (Option)
Program Dry Function Remote
Controller
Wireless 
Fan Only  Wired 
Lifestyle
Convenience
New POWERFUL Operation
(Non-Inverter)
——
Inverter POWERFUL Operation 
Priority-Room Setting
COOL / HEAT Mode Lock
HOME LEAVE Operation
ECONO Operation 
Indoor Unit ON/OFF Button 
Signal Receiving Sign 
Temperature Display
Another Room Operation
Note: : Holding Functions
— : No Functions

Table of Contents

Other manuals for Daikin J-Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin J-Series and is the answer not in the manual?

Daikin J-Series Specifications

General IconGeneral
BrandDaikin
ModelJ-Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals