Operation
20
English
MODE Usage and Function
AUTO FAN
Automatic airow rate adjustment
FAN setting (Quiet, Low, Standard, High) is automatically adjusted according to the degree of air
impurity.
Purifying capacity increases as airow rate rises.
If operating sound is a concern, airow rate can be changed.
Page 25, 26
Maximum airflow rate during AUTO FAN MODE is High, which is lower than Turbo.
Degree of air impurity corresponds to the volume of dust and the intensity of the odours in the
ambient air.
ECONO
Saving energy
In power saving mode within ECONO MODE, the FAN setting automatically switches between
Quiet and Low only. Power consumption (1) and operating sounds are minimised.
If the air is clean, after about 5 minutes, Monitoring mode automatically activates.
Recommended for use during sleep hours.
1 By comparison to AUTO FAN MODE (approx. 14.3Wh), power consumption in ECONO MODE
(approx. 7.4Wh) is approx. 6.9Wh lower.
Test condition case in Malaysia: Operation in 12.4m² room over 1 hour. Assuming 1 cigarette was
smoked immediately after the unit was turned on.
Power saving
mode
FAN setting switches
automatically with an
airow rate of Quiet or
Low.
Monitoring
mode
The fan starts and stops
periodically. Dust and odours are
monitored.
The following functions are turned
OFF to further reduce power
consumption.
Streamer
OFF
Active Plasma Ion
OFF
If the air is clean,
after about 5
minutes...
If dust or odours are
detected...
As the FAN setting is limited to Quiet and Low, air purifying capacity is reduced.
Since the air in the room is not drawn in while the fan is stopped, the sensitivity of the PM2.5 sensor
and odour sensor will decrease. To prevent this reduction in sensitivity, turn Monitoring mode OFF.
Page 25, 26
PET
Living with pets
A gentle air current is created by switching between the FAN setting between Standard and Low
every 5 minutes to continuously remove pet's hair.
The airflow cannot be manually controlled in this mode.
CIRCULATOR
When you want to circulate the air in the room
The air in the room is kept clean and local variations in temperature are suppressed. It is even
more effective if the unit is installed opposite an air conditioner.
The airow rate is High for about 30 minutes after operation start, in order to circulate the air in
the room.
After that, temperature change around the unit is monitored and FAN setting is automatically
adjusted.
(There is no temperature adjustment function)
If the indoor temperature is low, FAN setting may not be set to High.
(To reduce chills caused by airflow)