EasyManuals Logo

Daikin R32 Split Series Installer's Reference Guide

Daikin R32 Split Series
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
14 | Troubleshooting
Installer reference guide
106
EKHWET90~120BAV3
R32 Split series – Domestic hot water tank
4P680077-1 – 2021.11
INFORMATION
If an U8‑04 error occurs, the error can be reset after a successful update of the
software. If the software is not successfully updated then you must make sure that
your USB device has the FAT32 format.
INFORMATION
If the booster heater overheats and is disabled by the thermostatic safety, the unit
will not give an error directly. Check if the booster heater is still in operation if you
experience one or more of the following errors:
Powerful operation takes a very long time to heat up and the error code AJ-03 is
displayed.
During anti-legionella operation (weekly), the error code AH-00 is displayed
because the unit cannot reach the requested temperature required for tank
disinfection.
INFORMATION
A malfunctioning booster heater will have an impact on energy metering and power
consumption control.
INFORMATION
The user interface will display how to reset an error code.

Table of Contents

Other manuals for Daikin R32 Split Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin R32 Split Series and is the answer not in the manual?

Daikin R32 Split Series Specifications

General IconGeneral
BrandDaikin
ModelR32 Split Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals