10 | Configuration
Installer reference guide
78
EKHWET90~120BAV3
R32 Split series – Domestic hot water tank
4P680077-1 – 2021.11
# Code Description
[5.G] [A-01] Priority schedule:
▪ 0: Efficient: Booster heater is
prohibited
(a)
, except when outdoor unit is
unable to do DHW (see Priority schedule)
▪ 1: Quick: Booster heater is allowed to assist
heat pump during DHW production
[5.H] [8-03] When Quick is selected, the booster heater
can start after a delay timer to assist the heat
pump operation. The delay time is depending
on the selected Quick mode timer:
▪ Turbo (10 minutes)
▪ Normal (20 minutes)
▪ Economic (30 minutes)
(a)
When tank disinfection is performed with Efficient mode, the booster heater can still start
after 20 minutes to assist the heat pump.
10.6.3 User settings
Overview
The following items are listed in the submenu:
User settings
Information
Tank
Malfunctioning
Installer settings
[7] User settings
[7.1] Language
[7.2] Time/date
[7.3] Holiday
[7.4] Quiet
Language
# Code Description
[7.1] N/A Language
Time/date
# Code Description
[7.2] N/A Set the local time and date
INFORMATION
By default, daylight savings time is enabled and clock format is set to 24 hours. These
settings can be changed during initial configuration or via the menu structure [7.2]:
User settings > Time/date.
Holiday
About holiday mode
During your holiday, you can use the holiday mode to deviate from your normal
schedules without having to change them. While holiday mode is active, domestic
hot water operation will be turned off. Anti-legionella operation will remain active.