• Outdoor Unit • REYQ-T
1
• VRV Systems • REYQ-T
2
1 Features
Outdoor Uni VRV Systems REYQ-TVRV IV heat
Best efficiency & comfort solution
• Fully integrated solution with heat recovery for maximum efficiency
with COPs of up to 8 !
• Covers all thermal needs of a building via a single point of contact:
accurate temperature control, ventilation, hot water, air handling units
and Biddle air curtains
• "Free" heating and hot water production provided by transferring heat
from areas requiring cooling to areas requiring heating or hot water
• The perfect personal comfort for guests/tenants via simultaneous
cooling and heating
• Incorporates VRV IV standards & technologies: Variable Refrigerant
Temperature, continuous heating, VRV configurator, 7 segment
display and full inverter compressors, 4-side heat exchanger,
refrigerant cooled PCB, new DC fan motor
• Customize your VRV for best seasonal efficiency & comfort with the
weather dependant Variable Refrigerant Temperature function.
Increased seasonal efficiency with up to 28%. No more cold draft by
supply of high outblow temperatures
• Continuous comfort: Unique continuous heating technology makes
VRV IV the best alternative to traditional heating systems
• VRV configurator software for the fastest and most accurate
commissioning, configuration and customisation
• Outdoor unit display for quick on-site settings and easy read out of
errors together with the indication of service parameters for checking
basic functions.
• Free combination of outdoor units to meet installation space or
efficiency requirements
• Fits any building as also indoor installation is possible as a result of
high external static pressure of up to 78.4 Pa. Indoor installation
leads to less piping length, lower installation costs, increased
efficiency and better visual aesthetics
• Simplified installation & guaranteed optimal efficiency with automatic
charging & testing
• Easy compliance with F-gas regulation thanks to automated
refrigerant containment check
• Wide piping flexibility: 30m indoor height difference, maximum piping
length: 190m, total piping length: 1,000m
• Possibility to extend the operation range in cooling down to -20°C for
technical cooling operation such as server rooms
• The ability to control each conditioned zone individually keeps VRV
system running costs to an absolute minimum
• Spread your installation cost by phased installation
• Keep your system in top condition via our ACNSS service: 24/7
monitoring for maximum efficiency, extended lifetime, immediate
service support thanks to failure prediction and a clear understanding
of operability and usage
Inverter