Outdoor Unit • REYQ-T
1
VRV Systems • REYQ-T
2
1 Features
Outdoor Uni VRV Systems REYQ-TVRV IV heat
Best efficiency & comfort solution
Fully integrated solution with heat recovery for maximum efficiency
with COPs of up to 8 !
Covers all thermal needs of a building via a single point of contact:
accurate temperature control, ventilation, hot water, air handling units
and Biddle air curtains
"Free" heating and hot water production provided by transferring heat
from areas requiring cooling to areas requiring heating or hot water
The perfect personal comfort for guests/tenants via simultaneous
cooling and heating
Incorporates VRV IV standards & technologies: Variable Refrigerant
Temperature, continuous heating, VRV configurator, 7 segment
display and full inverter compressors, 4-side heat exchanger,
refrigerant cooled PCB, new DC fan motor
Customize your VRV for best seasonal efficiency & comfort with the
weather dependant Variable Refrigerant Temperature function.
Increased seasonal efficiency with up to 28%. No more cold draft by
supply of high outblow temperatures
Continuous comfort: Unique continuous heating technology makes
VRV IV the best alternative to traditional heating systems
VRV configurator software for the fastest and most accurate
commissioning, configuration and customisation
Outdoor unit display for quick on-site settings and easy read out of
errors together with the indication of service parameters for checking
basic functions.
Free combination of outdoor units to meet installation space or
efficiency requirements
Fits any building as also indoor installation is possible as a result of
high external static pressure of up to 78.4 Pa. Indoor installation
leads to less piping length, lower installation costs, increased
efficiency and better visual aesthetics
Simplified installation & guaranteed optimal efficiency with automatic
charging & testing
Easy compliance with F-gas regulation thanks to automated
refrigerant containment check
Wide piping flexibility: 30m indoor height difference, maximum piping
length: 190m, total piping length: 1,000m
Possibility to extend the operation range in cooling down to -20°C for
technical cooling operation such as server rooms
The ability to control each conditioned zone individually keeps VRV
system running costs to an absolute minimum
Spread your installation cost by phased installation
Keep your system in top condition via our ACNSS service: 24/7
monitoring for maximum efficiency, extended lifetime, immediate
service support thanks to failure prediction and a clear understanding
of operability and usage
Inverter