SiBE041010 Outdoor Unit
Removal Procedure 123
2
Remove the 3 screws
(right: 1 screw, left: 2
screws) and remove the
top panel.
3
Remove the 6 screws
of the front panel.
4
Lift up the left side and
unfasten the hooks.
5
Unfasten the right side
hooks and remove the
front panel.
6
7
The discharge grille has
2 projections to prevent
rotating. Press the
projections from the
rear side and rotate the
discharge grille.
Unfasten the 6 hooks
and remove the
discharge grille.
Step
Procedure Points
DAIKIN
INVERTER
Top panel
Front panel
(R12004)
INVERTER
DAIKIN
(R7944)
DAIKIN
INVERTER
Front panel
(R7945)
DAIKIN
INVERTER
Discharge grille
Projection (rear side)
(R7946)