Note: When Power over Ethernet (PoE) is available, the external
power supply is not required.
3.2. IP address
In order to access the d&b Remote network, the R70 interface must
have the same IP network settings as your network. Depending on the
network topology, the IP address can either be assigned manually or
automatically (DHCP).
When the R70 is connected to a network with a DHCP server present, a
matching IP address is assigned to the interface automatically.
In all other cases the R70 must be adapted manually.
The R70 IP address is set to 192.168.1.70 by factory default
(see also the label sticker on the rear panel of the R70).
3.3. Direct connection
To access the R70, manually assign an IP address to the PC on your
network with the same subnet as the R70. Proceed as follows:
1. From the "Start-Settings" menu select the "Network
Connection" associated with your network adapter.
2. Select "Internet Protocol (TCP/IP)" and click on "Properties".
3. Enter a static IP address in the same subnet as the R70 by
selecting "Use the following IP address":
IP address: 192.168.1.71
Subnet mask: 255.255.255.0
4. Apply the changes by clicking OK and close the network
properties dialog.
To display the web interface of the R70, enter the IP address of the R70
in the address bar of your web browser.
Page 12 of 20 R70 Ethernet to CAN interface, Manual