120 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Level Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
POWER switch off 0.09 0.07 1 0 1 3 1
Standby 0.17 0.44 9 0 9 31 8
On, idling 1.57 0.89 168 0 168 573 144
Signal CF 12 dB cont. 4 Ω/Ch. 25.50 0.98 3000 2150 850 2900 731
Signal CF 9 dB cont. 4 Ω/Ch. 30.00 0.98 3600 2600 1000 3412 860
Signal CF 9 dB max. 4 Ω/Ch. 54.00 0.99 6400 4000 2400
100 V AC / 60 Hz / 0.2 Ω Source impedance
Mode/Level Load
Line
current
A
RMS
Power
factor
Input
power
W
Output
power
(sum.) W
Power
loss
W
Thermal
dissipation
BTU/hr
Thermal
dissipation
kCal/hr
POWER switch off 0.08 0.07 1 0 1 2 0
Standby 0.17 0.50 9 0 9 31 8
On, idling 1.82 0.91 163 0 163 556 140
Signal CF 12 dB cont. 4 Ω/Ch. 32.50 0.99 3250 2150 1100 3753 946
Signal CF 9 dB cont. 4 Ω/Ch. 29.00 0.99 2900 2000 900 3071 774
Signal CF 9 dB max. 4 Ω/Ch. 55.00 0.99 5500 3500 2000