The digits indicate the set value as follows:
No. Parameter settings Settings range
Default
WT-D/DR WT-P/PR
P01 Working mode
01: Manual
02: Advanced Programmable Timer
NA 02
P02 Temperature control mode
01: Only room temp.;
02: Room and oor temp.;
03: Only oor temp.
01 01
P03 High room temp. limit 5-35° C (only for 01 and 02 in P02) 30° C 30° C
P04 Low room temp. limit 5-35° C (only for 01 and 02 in P02) 5° C 5° C
P05 Floor temp. limitation mode
01: High temp. limitation;
02: Low temp. limitation (only for 02 in P02)
01 01
P06 Floor temp. limitation setpoint 20-45° C (only for 02 in P02) 35° C 35° C
P07 High oor temp. limit 20-45° C (only for 03 in P02) 35° C 35° C
P08 Low oor temp. limit 20-45° C (only for 03 in P02) 20° C 20° C
P09 Frost protection 01: Enable; 02: Disable 01 01
P10 Frost protection setpoint 5-17° C 5° C 5° C
P11 Timer display option 01: 24 h; 02: 12 h NA 01
P12
Room temp. display option at
shutdown
01: No display current temp.;
02: Display current temp.
01 01
P03 to P08 appear on relevant temperature control mode.
10 Error Messages
E1 Room sensor failure
E2 Floor sensor failure
EE EEPROM failure
Lo Temperature lower than 0° C
Hi Temperature higher than 50° C
All relay output will be turned o in all cases.