User Guide BasicPlus
2
Room Thermostats
03/2015 VUCUA212 Danfoss Floor Heating Hydronics
3
The function consists of 2 programs:
P1 with 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.) P2 with 4 events in 2 days (Sat. Sun.).
P1: Press to display Mo. Tu. We. Th. Fr.
P1, Event 1:
1. Use < or > to select the start time.
2. Press to accept the setting.
3. Use < or > to select the temperature.
4. Press to accept the setting.
P1, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
P2: Sa. Su. are now shown in the display.
P2, Event 1:
1. Use < or > to select the start time.
2. Press to accept the setting.
3. Use < or > to select the temperature.
4. Press to accept the setting.
P2, Event 2-4:
Repeat the Event 1 procedure for programming
Event 2-4.
The thermostat will continue the 4-event program based on the present time and day.
To set and change the room temperature temporarily:
1. Press < or > at any time to change the desired temperature value. SET is shown in the display.
2. When releasing the < or >, the display returns to showing the actual temperature. This temperature change is
only temporary and will be maintained only until the next programmed setting!
A default program provides timer control if the customer does not create own programs:
Days Event 1 Event 2 Event 3 Event 4
Start time Temp. Start time Temp. Start time Temp. Start time Temp.
Mon - Fri 6:30
20° C
(27° C)*
8:30
15° C
(25° C)*
16:30
20° C
(27° C)*
22:30
15° C
(25° C)*
Sat - Sun 7:30
20° C
(27° C)*
9:30
20° C
(27° C)*
16:30
21° C
(28° C)*
22:30
15° C
(25° C)*
* Floor temperature control mode.
7 Check Floor Temperature
Press M and hold. Press < within 6 seconds.
ashes and the current oor temperature is displayed. Operate again, then exit (automatic exit after 6
seconds with no operation).
8 Child Safety Lock
Press M and hold. Press > within 6 seconds to lock all buttons.
Press again to exit the child safety lock.
9 Set Control Parameters
Press M button for 6 seconds to enter the parameter setting mode. Press M for parameter selection and set the
parameter range via < or >. Complete all adjustments.
To exit WT-P/PR, press , which is available for this purpose (automatic exit after 30 seconds with no operation).
To exit WT-D/DR, wait for automatic exit (30 seconds). The upper digits indicate the parameter number.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss BasicPlus2 and is the answer not in the manual?

Danfoss BasicPlus2 Specifications

General IconGeneral
BrandDanfoss
ModelBasicPlus2
CategoryThermostat
LanguageEnglish

Related product manuals