Danfoss – 23VUBMA102
3.2.2  Sub-menu OPERATION
In the OPERATION menu you can set the operating 
mode of the heat pump. 
When changing operating mode, confirm your 
choice by pressing the right button once. The aster-
isk moves to the selected operating mode.
For further information, see the ”Setting operating 
mode” section.
Menu text Description Adjusted by:
 (OFF)
The installation is fully switched off.
Remember that if the operating 
mode OFF is to be used for long 
periods during the winter, the 
water in the heating system in 
the installation must be drained, 
otherwise there is a risk of frost 
damage.
⚠
By the customer,  
if necessary.
AUTO
The heat pump and the auxiliary heater 
are automatically controlled by the con-
trol computer.
By the customer,  
if necessary.
HEATPUMP
The control computer is controlled so 
that only the heat pump unit (compres-
sor) is allowed to operate.
By the customer,  
if necessary.
ADD. HEAT
The control computer only permits the 
auxiliary heater to be in operation. This 
operating mode can be used when a new 
installation is being used, when the brine 
system is not ready for operation.
By the customer,  
if necessary.
HOT WATER
In this mode the heat pump only produc-
es hot water, no heat goes to the heating 
system.
By the customer,  
if necessary.
AUTO                   *
HEATPUMP
ADD. HEAT
HOT WATER
OPERATION