Danfoss – 24 VUBMA102
3.2.3 Sub-menu HEATCURVE
In the HEATCURVE menu the settings that affect the
indoor temperature are made. For further informa-
tion, see the About your heat pump section.
Menu text Description Adjusted by:
CURVE The set value indicates the supply line
temperature of the water that is trans-
ported to the heating system at an out-
door temperature of 0°C.
By the customer,
if necessary.
MIN Sets the lowest permitted supply tem-
perature.
By the customer,
if necessary.
MAX Sets the highest permitted supply tem-
perature.
By the customer,
if necessary.
CURVE 5 Used to adjust the heat curve at an out-
door temperature of +5°C.
By the customer,
if necessary.
CURVE 0 Used to adjust the heat curve at an out-
door temperature of 0°C.
By the customer,
if necessary.
CURVE - 5 Used to adjust the heat curve at an out-
door temperature of -5°C.
By the customer,
if necessary.
HEATSTOP This function stops all production of
heat when the outdoor temperature is
equal to, or higher than, the set heat stop
value.
By the customer,
if necessary.
REDUCTION The temperature can be lowered using
an outside timer. The control computer
determines the drop.
By the customer,
if necessary.
HEATCURVE
CURVE 40°C
MIN 22°C
MAX 70°C
CURVE 5 0°C
CURVE 0 0°C
CURVE -5 0°C
HEATSTOP 17°C