EasyManuals Logo
Home>Danfoss>Thermostat>ECtemp Smart

Danfoss ECtemp Smart User Manual

Danfoss ECtemp Smart
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
Danfoss ECtemp™ Smart
Installation Guide16
Error
type
Nr. Description Solu-
tion
Need restart
Floor
Sensor
discon-
nected
E1 Connection
to sensor is
lost
Contact
service
The thermostat
requires a restart
to operate again.
Floor
Sensor
short-
circuited
E2 Sensor
short-
circuited
Contact
service
The thermostat
requires a restart
to operate again.
Ther-
mostat
over-
heated
E3 Thermostat
is over-
heated,
heating is
turned o
Wait
until
ther-
mostat
cools
down
The thermostat
requires no
restart, but will
start heat-
ing when the
temperature is
lowered
Unrecov-
erable
error
E4 Room
temperature
sensor value
too high or
too low
Contact
service
The thermostat
requires a restart
to operate again.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ECtemp Smart and is the answer not in the manual?

Danfoss ECtemp Smart Specifications

General IconGeneral
BrandDanfoss
ModelECtemp Smart
CategoryThermostat
LanguageEnglish

Related product manuals