Danfoss ECtemp™ Smart
Installation Guide4
More information on this product can also be found at:
http://heating.danfoss.com/new-solutions/ectemp-smart
2 Technical Specications
Operation voltage 220-240 V~, 50/60 Hz
Standby power consumption Max. 0,40 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
Max. 1 A cos φ= 0,3
Transmission Frequency 2,4 - 2,483.5 GHz
Transmission Power < 20 dBm
Sensing units NTC 6,8 kOhm at 25°C
NTC 10 kOhm at 25°C
NTC 12 kOhm at 25°C
NTC 15 kOhm at 25°C (Default)
NTC 33 kOhm at 25°C
NTC 47 kOhm at 25°C
Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
42 kOhm
18 kOhm
6 kOhm
Control PWM (Pulse Wide Modulation)