5Installation Guide
Ambient temperature 0 ° to +30 °C
Frost protection
temperature
5 °C to +9 °C (default 5 °C)
Temperature range Room temperature: 5-35 °C.
Floor temperature: 5-45 °C.
Max. oor: 20-35 °C (if unrecov-
erable seal is broken then up to
45 °C). Min. oor: 10-35 °C, only
with combination of room and
oor sensor.
Sensor failure monitoring The thermostat has a built-in
monitoring circuit, which will
switch o the heating if the
sensor is disconnected or short-
circuited
Cable specication max. 1x4 mm
2
Ball pressure test temperature 75 °C
Pollution degree 2 (domestic use)
Controller type 1C
Software class A
Storage temperature -20 °C to +65 °C
IP class 21
Protection class Class II -