Danfoss ECtemp Touch
3Installation Guide
An installation wizard with room/oor type-specic
setup.
Support for multiple frame systems.
Compatible with several 3rd party NTC sensors.
Thermostat settings can be specied before instal-
lation and imported to the thermostat using a
web-generated code, or copied from a thermostat in a
similar installation.
Smart access to thermostat settings after installa-
tion by using a web code interface for easy setup or
remote troubleshooting.
More information on this product can also be found at:
electricheating�danfoss�com
1�1 Technical Specications
Operation voltage 220-240 V~, 50/60 Hz
Standby power consumption Max. 0.40 W
Relay:
Resistive load
Inductive load
Max. 16 A / 3680 W @ 230 V
cos φ= 0.3 Max. 1 A
Sensing units NTC 6.8 kΩ at 25°C
NTC 10 kΩ at 25°C
NTC 12 kΩ at 25°C
NTC 15 kΩ at 25°C (Default)
NTC 33 kΩ at 25°C
NTC 47 kΩ at 25°C