EM-PMI375-T500 options (continued)
Variant Code Description Additional information
Marine classification * No marine classification
+CL1 ABS American Bureau of Shipping
+CL2 BV Bureau Veritas
+CL3 DNV
+CL4 LR Lloyd’s Register
+CL5 RINA
EM-PMI375-T800 options
Variant Code Description Additional information
High voltage connections * One 3 phase system One connection box containing one 3
phase system with one M25 cable gland
per phase
-DUAL Two galvanically isolated 3
phase systems
Two connection boxes each containing
one 3 phase system with one M25 cable
gland per phase
-TRI Three galvanically isolated
3 phase systems
Two connection boxes one containing one
3 phase system and another one
containing two 3 phase systems with one
M25 cable gland per phase
Low voltage connections * Low voltage connections
done with connector
DEUTSCH HD34-24-47PE connector for LV
connections
+LVB1 Low voltage connections
done with connection box
and terminal strip
Connection box with 2x M25 cable glands
(reserve 2x plugged M16 threads
available) and terminal block for LV
connections
N-end attachment * Flange SAE 4 flywheel housing
+NE2 Male shaft + Flange DIN5480 W50x2x24x8f + SAE 4 flywheel
housing
Bearing lubrication and
mounting direction
* Greased for life Deep groove ball bearing, contact seal on
both sides, any mounting direction (see
user guide for details)
+BHS Grease lubricated Deep groove ball bearing, open design,
horizontal mounting direction (see user
guide for details)
Bearing insulation * Non-insulated bearings Non-insulated bearings
+BIN Insulated bearing in N-end Insulated bearing in N-end
+BIA Insulated bearing in both
ends
Insulated bearing in both ends
Shaft grounding * None
+SG1 D-end shaft grounding In-built grounding ring
Protection class * Standard protection class IP65 protection class
+IP67 IP67 protection class IP67 protection class, not available with
+BHS option
Cable direction * Cable direction fixed Cable direction towards D-end
+CNE Cable direction towards N-
end
Cable direction towards N-end
User Guide
EM-PMI375
General information
 
8 | 
©
 Danfoss | November 2021 BC265856307805en-000202