User manual ERC 113 refrigeration controller
"o2C"
Default dEF
D02 Config/o2C
D03 Config/o3C
D04 Config/o4C
D05 Config/o5C
"no": not used.
"dEF": electric defrost heater/valve for hot gas.
"ALA": alamr output.
"FAn": fan control.
"Lig": light control.
"o3C"
Default FAn
"o4C"
Default Lig
"o5C"
Default no
"b1C"
Default noP
Lower left button:
Button 1 Config (short press)/b1C
Button 1 Config (long press)/b1L
Upper left button:
Button 2 Config (short press)/b2C
Button 2 Config (long press)/b2L
Upper right button:
Button 3 Config (short press)/b3C
Button 3 config (long press)/b3L
Lower right button:
Button 4 Config (short press)/b4C
Button 4 Config (long press)/b4L
"b1L"
Default PoF
"b2C"
Default dEF
"b2L"
Default inF
"b3C"
Default tP
"b3L"
Default ECo
"b4C"
Default tn
"b4L"
Default Lig
"b5C"
Default noP
Button 5 Config (short press) / b5C
Button 5 Config (long press) / b5L
"b5L"
Default noP
"PS1"
Min. 0
Max. 999
Default 0
Password level 1 / PS1
Password Level 2 / PS2
Password Level 3 / PS3
These assign passwords to the three levels of access. The password is a
three-digit number. Access levels are Shop, Service and OEM.
You may not therefore have access to change all the passwords.
Passwords are entered by using the up and down arrow buttons.
Danfoss advises against using passwords which are easy to remember
or enter, for example 111, 222, 123 etc.
NOTE: When accessing the controller with 3 wrong password in a sequence
ERC will automatically block access for 15 minutes.
"PS2"
Min. 0
Max. 999
Default 0
"PS3"
Min. 0
Max. 999
Default 0
The buttons can be programmed as follows:
Short press function Long press function
"noP": not operating
"tP": increase set point
"tn": decrease set point
"ECo": toggle Eco mode
"Lig": toggle light
"dEF": toggle defrost
"SuP": toggle super-cool/pull down
"diP" : increase display intensity
"din" : decrease display intensity
"CFA": toggle °C and °F
"noP": not operating
"tP": increase set point
"tn": decrease set point
"ECo": toggle Eco mode
"Lig": toggle light
"dEF": toggle defrost
"SuP": toggle super-cool/pull down
"diP": increase display intensity
"din": decrease display intensity
"CFA": toggle °C and °F
"PoF": ERC power ON/OFF
"HoL": enter holiday mode
"inF": enter info menu
NOTE: Your assignments may not be shown on the printed buttons. We advice to
use this functionality together with the fully integrated mounting model only.
1
23
4
Short press function Long Press function
"noP": not operating
"ECo": toggle ECO mode
"SuP": toggle super-cool/pull down
"Lig": toggle light
"dEF": toggle defrost
"noP": Not operating
"ECo": Toggle Eco mode
"SuP": Toggle Super-Cool /Pull-down
"Lig": Toggle light
"dEF": Toggle defrost
"PoF": ERC power ON/OFF
"HoL": enter holiday mode
Produced by Danfoss A/S (ADAP-KOOL®) | 2016-07
19
DKRCC.ES.RL0.F5.02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss ERC 113D and is the answer not in the manual?

Danfoss ERC 113D Specifications

General IconGeneral
BrandDanfoss
ModelERC 113D
CategoryController
LanguageEnglish

Related product manuals