www.danfoss.com/erc
User manual | ERC 21X temperature controllers series
4
push buttons, a
big display and
an intuitive menu
structure ensure
superior ease of use.
ERC 21X, smart multipurpose
refrigeration controller

Other manuals for Danfoss ERC 213

Questions and Answers:

Danfoss ERC 213 Specifications

General IconGeneral
Supply Voltage230 V AC
Dimensions75 x 33 x 85 mm
Digital Inputs2
Enclosure RatingIP20
Input Voltage230 V AC
Housing MaterialPlastic
ApplicationRefrigeration
Storage Temperature-20 - 70 °C
Relative Humidity20% to 80% non-condensing
Protection ClassClass II
Weight0.2 kg
Operating Temperature-10°C to +50°C
Power Consumption3 W

Summary

Introduction to ERC 21 X Controllers

1.1 Application Areas

ERC 21X is a multipurpose refrigeration controller for commercial applications.

1.2 General Description

Features like push buttons, display, intuitive menu, and energy efficiency.

ERC 21 X Series Variants

1.3.1 ERC 211 Model Details

Details about ERC 211: one relay output, two inputs, applications.

1.3.2 ERC 213 Model Details

Details about ERC 213: three relays outputs, four inputs, applications.

1.3.3 ERC 214 Model Details

Details about ERC 214: four relays outputs, four inputs, applications.

Key Controller Features

2.1 Voltage Protection

Protects compressor from high/low voltage by limiting operation.

2.2 Compressor Protection

Protects compressor by managing ON/OFF times to prevent short cycling.

2.3 High Condensing Temperature Protection

Warns and stops compressor if condensing temperature is too high.

Pre-defined Application Modes

2.4 Pre-defined Applications

Configures controller for specific applications like storage temp & defrost type.

Fan Operation Features

2.5 Fan Pulsating During Compressor OFF Cycle

Energy saving feature that runs fan during compressor OFF cycle.

Advanced Control Functions

2.6 Defrost on Demand

Triggers defrost based on evaporator temperature and ice buildup.

Technical Specifications

Installation Guide

4.1 Dimensions and Drilling Template

Provides physical dimensions and drilling template for the controller.

4.2 Mounting Instructions

Illustrates the mounting and unmounting process of the controller.

4.3 Installation Steps

Step-by-step guide for physically installing the controller.

Electrical Connections

4.4.1 ERC 211 Connection Diagram

Wiring diagram for connecting the ERC 211 controller.

4.4.2 ERC 213 Connection Diagram

Wiring diagram for connecting the ERC 213 controller.

4.4.3 ERC 214 Connection Diagram

Wiring diagram for connecting the ERC 214 controller.

Controller Setup and Configuration

4.5 Power Supply Requirements

Specifies voltage requirements for the controller.

4.6 Sensor Configurations

Lists sensor types and their designations (Sair, S5, Sc, Di1, Di2).

4.7 Electrical Noise Prevention

Guidelines for preventing electrical interference with cables.

Menu Navigation and User Interface

5.1 Key Functions and Display Icons

Explains button functions and icons displayed on the controller.

5.2 Quick Configuration at Power Up

Guides the user through initial setup and application selection.

Menu Structure and Operation

5.3 Menu Structure Overview

Visual representation of the controller's menu hierarchy and navigation.

Parameter Configuration Procedures

5.4 Quick Configuration via CFG Menu

Detailed steps for configuring the controller using the 'cfg' menu.

5.5 Adjusting Setpoint Temperature

Instructions on how to change the target temperature setpoint.

5.6 Initiating Manual Defrost

How to manually trigger a defrost cycle.

5.7 Initiating Pull Down Cycle

How to initiate a pull-down cycle.

5.8 Viewing Active Alarms

How to view current active alarms.

5.9 Unlocking the Keyboard

Instructions to unlock the controller's keypad.

Detailed Menu Functions

Configuration Parameters

Parameters for general setup, main switch, and application selection.

Reference & Thermostat Parameters

Parameters for temperature setpoint, differential, and limits.

Defrost Parameters

Parameters controlling defrost cycles, methods, and timing.

Alarm Parameters

Parameters for setting up temperature and voltage alarms.

Fan Control Parameters

Parameters for configuring fan operation modes and settings.

Compressor Parameters

Parameters for compressor operation, including minimum ON/OFF times.

Other Function Parameters

Miscellaneous parameters like output delays and DI configuration.

Input Polarity Settings

Settings for input polarity of DI1 and DI2.

Keyboard Lock Enable

Enables or disables the keyboard lock feature.

Parameter Reference Tables

7.1 Parameter Table for ERC 211

Detailed parameter values for ERC 211 across different applications.

7.2 Parameter Table for ERC 213

Detailed parameter values for ERC 213 across different applications.

7.3 Parameter Table for ERC 214

Detailed parameter values for ERC 214 across different applications.

Troubleshooting and Ordering

7.4 Alarm Codes Explained

Lists alarm statuses and their corresponding error codes.

7.5 Troubleshooting Guide

Lists common problems, their probable causes, and remedies.

8 Ordering Information

Information on product types, descriptions, relays, and part numbers.