User Guide
Electronic Refrigeration Controller
ERC 112D VSC for variable speed
compressor
This user guide is intended to be used by OEMs for the purpose of
programming ERC 112D VSC. It may also be useful for technicians.
However, it is not intended as a user guide for end users.
www.danfoss.com/erc

Questions and Answers

  • L
    Linda WilliamsAug 16, 2025
    Why won't the compressor start on my Danfoss ERC 112D VSC Controller?
    • J
      joshua68Aug 16, 2025
      If the compressor on your Danfoss Controller isn't starting, it could be due to a faulty frequency table. You should check the frequency cable continuity and the connection of the frequency cable at both the controller and drive side.
  • J
    Jason WebbAug 19, 2025
    What to do if the Danfoss ERC 112D VSC display alternates between high and temperature?
    • C
      Carmen LawsonAug 19, 2025
      If the display on your Danfoss Controller alternates between 'high' and the temperature, it indicates that the temperature is too high. Check ALA->HAt to resolve this issue.
  • K
    Keith BarberAug 22, 2025
    Why does the Danfoss ERC 112D VSC Controller display alternate between low and temperature?
    • D
      Dr. Matthew Chan PhDAug 22, 2025
      If your Danfoss Controller display alternates between 'low' and the temperature, this means the temperature is too low. To fix this, check ALA -> LAt.
  • S
    Sean McconnellAug 25, 2025
    What causes the Danfoss ERC 112D VSC Controller display to alternate between condenser and temperature?
    • M
      Mary CastroAug 25, 2025
      If the display on your Danfoss Controller alternates between showing the condenser status and the temperature, it means the condenser is too hot. Clean the condenser and check Con ->CAL, CbL.
  • J
    Jonathon RayAug 28, 2025
    What to do if the fan does not start in Danfoss ERC 112D VSC?
    • G
      Gerald DanielAug 28, 2025
      If the fan on your Danfoss Controller isn't starting, it might be because the door is open or the door contact is defective. Check that the door contact is okay.
  • M
    Mrs. Alicia LaneAug 31, 2025
    Why doesn't the Danfoss Controller shift between ECO and normal mode on ambient light change?
    • B
      Bryce MiddletonAug 31, 2025
      If your Danfoss Controller isn't shifting between ECO and normal mode when the ambient light changes, it could be because the ambient light sensor is broken or the light level isn't set properly. Check Eng->SLd, SLn.
  • M
    Mary RomanSep 3, 2025
    What to do if the alarm does not sound on Danfoss ERC 112D VSC?
    • J
      Judith TranSep 3, 2025
      If the alarm on your Danfoss Controller isn't sounding, it could be because the alarm is delayed. Check ALA->Htd, Abd and Pud->Pdd.
  • E
    Edward WrightSep 5, 2025
    What to do if defrost does not start on Danfoss Controller?
    • D
      Danielle GarciaSep 6, 2025
      If defrost isn't starting on your Danfoss Controller, it might be because the controller is in pull-down mode. Check parameter Pud->Pdi.
  • H
    hclarkSep 9, 2025
    How to fix weak display brightness on Danfoss ERC 112D VSC?
    • A
      aaronhudsonSep 9, 2025
      If the display brightness on your Danfoss Controller is weak, the ambient light sensor might be broken. Replace the sensor.
  • D
    darren47Sep 12, 2025
    What does "dEf" mean on my Danfoss Controller display?
    • J
      James JonesSep 12, 2025
      If your Danfoss Controller display shows 'dEf', it indicates that a defrost is in progress. Check diS ->SdF.

Summary

Quick Programming Methods

Accessory Code Numbers

Controller Operation

Key Operational Tasks

Setting temperature, acknowledging alarms, and changing parameters.

Parameter Configuration: Thermostat and Fan

Thermostat Settings

Parameters for set point, differential, and temperature limits.

Parameter Configuration: Fan and Pull Down

Parameter Configuration: Defrost

Defrost Type and Termination

Settings for defrost type, termination temperature, and reset.

Defrost Intervals and Duration

Configuration for minimum/maximum defrost intervals and duration.

Parameter Configuration: Defrost Fan and Timing

Parameter Configuration: Compressor

Compressor Speed and Control

Settings for minimum, maximum, start, and defrost speeds.

PID and Frequency Settings

Configuration for PI controller gains and frequency settings.

Parameter Configuration: Display and Alarms

Parameter Configuration: Alarms and Heating

Parameter Configuration: ECO Mode

ECO Mode Activation and Triggers

Settings for enabling ECO mode via door actions or PIR.

Parameter Configuration: Inputs and Outputs

Input Signal Configuration

Defining sensor types and applications for inputs.

Parameter Configuration: Buttons and Security

Button Function Mapping

Assigning functions to controller buttons via short and long presses.

Password Protection Settings

Setting and managing password levels for access control.

Troubleshooting Guide

Problem Resolution

Common issues, probable causes, and recommended remedies.

Alarm Code Reference

Reference for alarm codes, triggers, and automatic clearance.

Sensor Placement Guidelines

Typical Application Examples

Danfoss ERC 112D VSC Specifications

General IconGeneral
BrandDanfoss
ModelERC 112D VSC
CategoryController
LanguageEnglish