Danfoss ERC 214 - User Manual

Danfoss ERC 214
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
www.danfoss.com/erc
User manual | ERC 21X temperature controllers series
4
push buttons, a
big display and
an intuitive menu
structure ensure
superior ease of use.
ERC 21X, smart multipurpose
refrigeration controller

Other manuals for Danfoss ERC 214

Questions and Answers

  • S
    Steven ParkerJul 25, 2025
    Why won't my Danfoss ERC 214 Controller's compressor start?
    • G
      Gregory McgrathJul 25, 2025
      Several factors can prevent the compressor from starting. It may be waiting for the compressor delay timer; in this case, check parameter C02. A defrost cycle might be in progress, so check parameters d03 and d19. Also, the line voltage to the compressor could be too low or too high; verify parameters A72, A73, and A75.
  • M
    Melissa OlsonJul 30, 2025
    What to do if the Danfoss Controller displays the wrong temperature?
    • R
      Regina MayerJul 30, 2025
      If the temperature displayed is incorrect, the wrong type of sensor might be selected. Verify the sensor type by checking parameter o06 in the cFg menu.
  • M
    Michael ChavezAug 3, 2025
    Why does defrost not start on my Danfoss ERC 214 Controller?
    • L
      Leslie DicksonAug 3, 2025
      If the defrost cycle isn't starting, the controller might be in pull-down mode. Check parameter r96 to confirm.
  • A
    Alexander CurtisAug 7, 2025
    Why does my Danfoss ERC 214 Controller display the wrong temperature?
    • O
      obradyAug 7, 2025
      The displayed temperature might be incorrect if the wrong type of sensor is selected. To resolve this, verify the sensor type setting by checking cFg ? o06.
  • M
    Matthew GriffithAug 11, 2025
    What to do if the compressor does not start on my Danfoss ERC 214 Controller?
    • R
      rbanksAug 11, 2025
      If the compressor fails to start, consider these potential causes: * The compressor delay timer might be active, so check c-- ?C02. * Defrost might be in progress, check d-- ? d03. * Line voltage to the compressor could be too low or too high, check A-- ? A72. Also check A-- ? A73 and A-- ? A75.
  • C
    Christine ClarkAug 15, 2025
    Why won't pull-down start on my Danfoss ERC 214 Controller?
    • I
      ikirbyAug 15, 2025
      Pull-down might not start if the pull-down max duration is set to 0, check r-- ? r96. Also, pull-down limit temperature might be too high, check r-- ? r97.
  • V
    Victor JacksonAug 20, 2025
    How to troubleshoot a Danfoss ERC 214 when pull-down does not start?
    • M
      Mary MooreAug 20, 2025
      If the pull-down function isn't initiating, it could be due to the pull-down maximum duration being set to 0, or the pull-down limit temperature being set too high. Check parameters r96 and r97 to adjust these settings.

Summary

Introduction to ERC 21 X Controllers

Application of ERC 21 X Controllers

Details the various commercial refrigeration applications for which the ERC 21X controller is suitable.

General Description of ERC 21 X Controllers

Provides an overview of the controller's features, including its interface, energy efficiency, and protection capabilities.

ERC 21 X Series Overview

Outlines the different versions available within the ERC 21X series and their basic specifications.

ERC 211 Model Details

Specifies the inputs, outputs, and applications for the ERC 211 controller model.

ERC 213 Model Details

Details the inputs, outputs, and applications for the ERC 213 controller model.

ERC 214 Model Details

Specifies the inputs, outputs, and applications for the ERC 214 controller model.

Key Features of the ERC 21 X Controller

Voltage Protection

Explains how the controller protects the compressor from low and high voltage conditions.

Compressor Protection

Details parameters for minimum ON and OFF times to protect the compressor from short cycling.

Protection Against High Condensing Temperature

Describes how the controller manages high condensing temperatures to protect the compressor.

Pre-defined Applications

Guides users on selecting pre-configured applications for easy setup based on specific refrigeration needs.

Fan Pulsating During Compressor OFF Cycle

Explains an energy-saving feature where the fan runs during compressor OFF cycles.

Defrost on Demand

Details the feature that initiates defrost based on monitored evaporator temperature, optimizing energy use.

Technical Specifications

Installation Guide for ERC 21 X Controllers

Dimensions

Provides the physical dimensions of the ERC 21X controller in millimeters.

Mounting Instructions

Illustrates and describes the procedure for mounting the controller onto a panel.

Installation Steps

Step-by-step guide for installing the controller, including sealing and clip usage.

Electrical Connection Diagrams

Wiring diagrams showing connections for ERC 211, ERC 213, and ERC 214 models.

Power Supply Requirements

Specifies the voltage and frequency requirements for the controller's power supply.

Supported Sensors

Lists the types of temperature sensors compatible with the ERC 21X controller.

Electric Noise Guidelines

Provides recommendations for managing electric noise to ensure proper sensor and input function.

Menu Navigation and Overview

Key Functions and Display Icons

Explains the function of each button and the meaning of the icons displayed on the controller.

Quick Configuration at Power Up

Guides the user through the initial setup process upon first powering the controller.

Menu Structure

Illustrates the hierarchical structure of the controller's menu system.

Quick Configuration via cFg Menu

Details the steps for accessing and using the configuration menu for initial setup.

Adjusting Set Point Temperature

Describes how to modify the desired temperature set point using the controller's interface.

Initiating a Manual Defrost

Explains the procedure to manually start a defrost cycle.

Initiating a Pull Down Cycle

Details the process for starting a pull down cycle, typically for rapid cooling.

Viewing Active Alarms

Shows how to access and view any active alarm codes displayed on the controller.

Unlocking the Keyboard

Provides instructions on how to unlock the controller's keypad if it has been automatically locked.

Menu Functions

Alarm Codes

Air Temperature Sensor (Sair) Error

Indicates an issue with the primary air temperature sensor.

Defrost Sensor (S5) Error

Signifies a problem detected with the evaporator defrost sensor.

Condenser Sensor (Sc) Error

Indicates an error with the condenser temperature sensor.

High Temperature Alarm

Triggered when cabinet temperature exceeds the high alarm limit.

Low Temperature Alarm

Triggered when cabinet temperature falls below the low alarm limit.

High Voltage Alarm

Indicates that the supply voltage has exceeded the maximum safe limit.

Low Voltage Alarm

Indicates that the supply voltage has dropped below the minimum safe limit.

High Condenser Temperature Alarm

Alerts when the condenser temperature reaches a critical high level.

Door Alarm

Indicates that a door has been left open for an extended period.

Standby Alarm

Indicates a general standby or system fault condition.

DI External Alarm

Signals an alarm triggered by a configured digital input.

Troubleshooting Common Issues

Compressor Does Not Start

Provides troubleshooting steps for when the compressor fails to start.

Defrost Does Not Start

Guides on diagnosing and resolving issues preventing the defrost cycle from initiating.

Pull-Down Does Not Start

Offers solutions for problems encountered when trying to start a pull-down cycle.

Wrong Temperature Displayed

Provides steps to resolve inaccuracies in the displayed temperature readings.

Ordering Information

Danfoss ERC 214 Specifications

General IconGeneral
TypeElectronic Room Controller
Control OutputRelay
Communication ProtocolModbus RTU
Protection ClassIP20
ApplicationRefrigeration systems
Input Voltage230 V AC
Mounting TypeDIN Rail
Relative Humidity20% to 80% (non-condensing)
Weight0.2 kg