| 123DKRCE.PI.RL0.F6.ML Instruction sheet | ERC 211
ITALIANO
9 - Elenco parametri
Nome parametro - ERC 211 Codice Min Max Unità
App. 0
(Sbr.)
App. 1 App. 2 App. 3 App. 4 App. 5
Configurazione cFg
Interruttore principale
-1=servizio, 0=OFF, 1=ON
r12 -1 1 1 1 1 1 1 1
Applicazioni predefinite
AP0, AP1, AP2, AP3, AP4, AP5
o61 AP0 AP5 AP0 AP1 AP2 AP3 AP4 AP5
Selezione tipo sensore
n5=NTC 5 K, n10=NTC 10 K,
Ptc=PTC, Pt1=Pt1000
o06 n5 Pt1 n10 n10 n10 n10 n10 n10
Riferimento/termostato r--
Setpoint temperatura r00 -100.0 200.0 C/F 2.0 8.0 4.0 4.0 40.0 2.0
Differenziale r01 0.1 20.0 K 2.0 2.0 2.0 2.0 2.0 2.0
Limitazione setpoint min. r02 -100.0 200.0 C/F -35.0 4.0 2.0 2.0 20.0 -35.0
Limite setpoint max. r03 -100.0 200.0 C/F 50.0 20.0 6.0 6.0 60.0 50.0
Offset display
(valore di correzione della temperatura a display)
r04 -10.0 10.0 K 0.0 0.0 0.0 0.0 0.0 0.0
Unità display (°C/°F) r05 -C -F -C -C -C -C -C -C
Calibrazione di Sair
(offset per la calibrazione della temperatura
dell’aria)
r09 -20.0 20.0 K 0.0 0.0 0.0 0.0 0.0 -
Interruttore principale
-1=servizio, 0=OFF, 1=ON
r12 -1 1 1 1 1 1 1 -
Setback notturno
(offset di temperatura in modalità notturna)
r13 -50.0 50.0 K 0.0 0.0 0.0 0.0 0.0 0.0
Spostamento di riferimento termostato
(offset di temperatura)
r40 -50.0 50.0 K 0.0 0.0 0.0 0.0 0.0 -
Durata pull-down r96 0 960 min 0 - 0 0 - -
Limite temperatura pull-down r97 -100.0 200.0 C/F 0.0 - 0.0 0.0 - -