| 141DKRCE.PI.RL0.H7.ML Installation Guide | ERC 214
DEUTSCH
Parametername – ERC 214 Code Min. Max.
Ein-
heit
Anw. 0
(Abtau-
ung)
Anw. 1 Anw. 2 Anw. 3 Anw. 4 Anw. 5 Anw. 6
Konfiguration cFg
Hauptschalter
-1 = Service, 0 = AUS, 1 = EIN
r12 -1 1 1 1 1 1 1 1 1
Vordefinierte Anwendungen
AP0, AP1, AP2, AP3, AP4, AP5, AP6
o61 AP0 AP6 AP0 AP1 AP2 AP3 AP4 AP5 AP6
Fühlertypauswahl
n5 = NTC 5 K, n10 = NTC 10 K,
Ptc = PTC, Pt1 = Pt1000
o06 n5 Pt1 n10 n10 n10 n10 n10 n10 n10
DO4-Konfiguration
Lig = Beleuchtung, ALA = Alarm
o36 Lig ALA Lig Lig Lig Lig Lig Lig Lig
Referenz/Thermostat r--
Temperatursollwert r00 -100.0 200.0 C/F 2.0 4.0 2.0 -24.0 2.0 -24.0 2.0
Differenz r01 0.1 20.0 K 2.0 2.0 2.0 2.0 2.0 2.0 2.0
Begrenzung min. Sollwert r02 -100.0 200.0 C/F -35.0 2.0 0.0 -26.0 0.0 -26.0 -35.0
Begrenzung max. Sollwert r03 -100.0 200.0 C/F 50.0 6.0 4.0 -20.0 4.0 -20.0 50.0
Display-Offset
(Korrekturwert der angezeigten Temperatur)
r04 -10.0 10.0 K 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Displayeinheit (°C/°F) r05 -C -F -C -C -C -C -C -C -C
Sair-Kalibrierung
(Offset zur Kalibrierung der Lufttemperatur)
r09 -20.0 20.0 K 0.0 0.0 0.0 0.0 0.0 0.0 -
Hauptschalter
-1 = Service, 0 = AUS, 1 = EIN
r12 -1 1 1 1 1 1 1 1 -
Nachtabsenkung
(Offset-Temperatur im Nachtmodus)
r13 -50.0 50.0 K 0.0 0.0 0.0 0.0 0.0 0.0 0.0
Sollwertverschiebung Thermostat
(Offset-Temperatur)
r40 -50.0 50.0 K 0.0 0.0 0.0 0.0 0.0 0.0 -
Dauer Schnellabkühlung r96 0 960 min 0 0 0 0 0 0 -
Grenztemperatur Schnellabkühlung r97 -100.0 200.0 C/F 0.0 0.0 0.0 0.0 0.0 0.0 -
Alarm A--
Verzögerung für den Temperaturalarm
unter normalen Bedingungen
A03 0 240 min 30 45 30 30 30 30 30
Hinweis: Verborgene Parameter sind grau dargestellt.
9 - Parameterliste