3. Remove stop (27) from directional spool (25).
Removing end cover at LS-connection
1.
Unscrew screws (8x81) with spring washer (8x80) using a 13 mm socket spanner and screw (83)
with spring washer (83) using a 10 mm Hex key.
2. Remove end cover (65).
Spring stops (10 and 30) and springs (28 and 29) will follow the end cover.