Assembling shock, suction, and check valve
1. Place O-ring (20.11) on shock and suction valve cartridge (20).
2. Place O-ring (37.3) on valve seat/housing (37.4).
a)
Place housing in a 17 mm socket spanner.
b)
Place ball (37.5), spring (37.2) and plug (37.1) in housing (37.4) and tighten, using a 4 mm
Hex key and a 17 mm socket spanner, 5 ± 1 N·m [45 ± 10 lbf·in].
3.
Place orifice (41) in plug (40) and tighten in the pin hole, using a 4 mm Hex key and a mandrel,
5 ± 1 N·m [45 ± 10 lbf·in].
Service Manual
OSQA/OSQB
Assembly
©
Danfoss | July 2016 HN25D293 | AX00000127en-US0101 | 25