Danfoss Heating
5
GB
Leave at least
25mm below
product
Rear entry
cable access
Cable aperture
knockouts
Wall or
plasterbox
xing
Terminal
block
Outline of
programmer
Leave suffi cient space for
screwdriver access
C/L
5. Referring to the wiring diagrams on page 6-10, connect the unit
as shown.
6. Ensure all dust and debris are cleared from the area.
7. Locate the module on the latches at the bottom of the wallplate
and hinge upwards to fully engage the unit connectors into the
wallplate. Tighten the two fi xing screws to secure the unit to the
wallplate.
8. Before setting the programme, check the unit and circuit. Switch
on the mains supply and press the rocker switch to the CONSTANT
position - the red LED should now be illuminated. Adjust any
remote thermostat to check the services operate correctly.
9. Press the rocker switch to the OFF position and check that the
system does not operate.
10. Finally, press the rocker switch to TIMED position prior to
programming the unit.