User guide SonoMeter 30
14 | VUIGI102 © Danfoss | 2018.01
5. Meter access and
configuration
The software “SonoMeter30UserConfig” is used to read and configure SonoMeter 30 device via OG-1-
USB optical reader (dongle).
Meter configuration can be done also via M-Bus interface module then converter COM/M-Bus (MB-1)
can be used.
Installation and using SonoMeter30UserConfg is described in chapter 5.2 .
5.1 Jumper placement and optical head
Some parameters can be changed only in test mode.
Fig. 5.1 Jumper setting for test mode Fig. 5.2 OG-1-USB optical head
Optical interface is integrated into the front panel of calculator. It is designed for data reading via
M-bus protocol and parameterization of the meter using OG-1-USB optical head. Or any other
standard according EN1434.
The optical interface is activated by pressing control button and automatically shuts off after 5
minutes, after the last pressing button or after completing data transmission via interface.
5.2 Pre-settings (delivery from factory)
M-Bus address Last two digits of serial number
Pulse interfaces: Pulse outputs
Pulse output 1: Energy [1 kWh/pulse]
Pulse output 2: Volume [1 L/pulse]
Yearly due date: 31.12.
Monthly due date
31. (if set up is 31, the data will be recorded on the last day of the
month)
History logs in display (monthly): Off (except previous month)
History logs in memory (monthly): Off (except previous month)
History logs in memory (daily, hourly): Off (except previous month)
Tariff functionality Not activated
MBus communication Limited to 90 sec sending interval
5.3 Software “SonoMeter30UserConfig”
5.3.1 Program installation
Program SonoMeter 30 UserConfig is used to read data from SonoMeter 30 device and to configure
meter by editing its parameters.
Microsoft Windows must have Microsoft NET FrameWork v3 installed. You can install SonoMeter 30
User - Config from SonoMeter 30 UserConfig.exe file. You will be asked to enter user name and your
organization.
Note: This is for advanced users
only.

Other manuals for Danfoss SonoMeter 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss SonoMeter 30 and is the answer not in the manual?

Danfoss SonoMeter 30 Specifications

General IconGeneral
BrandDanfoss
ModelSonoMeter 30
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals