© Danfoss | 2019.02 VU.E2.G1.02 | 1
PFM 1000 Balancing Measuring Device
User Guide for Mobile Devices with iOS
User Guide

Questions and Answers

  • M
    Molly BarreraAug 3, 2025
    How to fix Danfoss PFM 1000 Measuring Instruments when application doesn't connect?
    • T
      Travis ColonAug 3, 2025
      If the Danfoss Measuring Instruments application does not connect with the pressure unit, or the start or record reading stops, turn off the Bluetooth in your mobile device, turn it on again, and repeat the application’s function.
  • M
    Melissa MorrisAug 9, 2025
    What to do if Danfoss PFM 1000 Measuring Instruments cannot be turned on?
    • T
      tiffanymillerAug 9, 2025
      If your Danfoss Measuring Instruments cannot be turned on, check the batteries and replace them if necessary.
  • J
    jeremy44Aug 15, 2025
    What to do if the Danfoss PFM 1000 pressure unit Bluetooth search is not functional?
    • N
      nelsonmaryAug 15, 2025
      If the Danfoss Measuring Instruments pressure unit Bluetooth search is not functional, or the application is unable to connect after pressing Connect, turn the pressure unit off and on again, then repeat the requested application’s function.
  • R
    rgreenAug 21, 2025
    What to do if the green light is flashing on my Danfoss Measuring Instruments?
    • T
      tiffanystevensAug 22, 2025
      If the green light indicator on your Danfoss Measuring Instruments is flashing with a 1-second period, it means the Bluetooth module initialization is faulty. Turn the instrument off and on to resolve this.
  • G
    Gary GrayAug 27, 2025
    How to measure with a different pressure unit on Danfoss PFM 1000 Measuring Instruments?
    • N
      Nathan WilliamsAug 27, 2025
      If you have selected 'Always use selected device' and want to measure with a different pressure unit on your Danfoss Measuring Instruments, go to the Sensor setup / Always use Bluetooth address in the application setup. Delete the Bluetooth module address recorded there, and the application will search through all pressure units again.

Summary

Device Introduction

Instrument Features Overview

Details on the core features and capabilities of the PFM 1000 measuring unit.

Pressure Measuring Unit Details

Description of the physical unit and its pressure sensing components.

PFM 1000 App Installation

Application Configuration

Setting up initial features like units, sound, and default project settings.

Measuring Workflow

Device Power-On Procedure

Steps and indicators for turning on the PFM 1000 instrument.

Measuring Screen Interface

Overview of the main measuring screen and its displayed information.

Measuring Context Menu

Valve Selection & Presetting

Selecting a valve from the database and setting its preset value.

Medium & Kv Configuration

Choosing the heat-transfer medium and direct Kv setup.

Advanced Measurement Settings

Setting Requested Flow Rate

Displaying and setting the actual/requested flow ratio for balancing.

Specifying Medium Temperature

Manually entering the medium temperature for accurate flow calculation.

Measurement Prep & Quick Recording

Sensor Zeroing & Hose Deaeration

Procedure for resetting the pressure sensor and bleeding hoses.

Quick Record Functionality

Capturing and saving measurement data quickly.

Project Management Overview

Project Tab Details

Entering project data, file names, and initial pressure values.

Project Data Handling

Project Context Menu

Accessing options like New, Open, Save, Mail, Delete, and Rename projects.

Branches Tab Overview

Setting up and measuring parameters for individual branches within a project.

Branch Management

Branch Context Menu

Operations include adding, renaming, moving, and deleting branches.

Data Recording

Record Info Tab

Accessing record metadata and managing records via a context menu.

New Record Creation

Selecting quantities, medium, temperature, valve, and setting record intervals.

Recorded Data Management

Record Access & Sharing

Opening, reading, sending records via email, and deleting records.

Record Items Tab

Viewing detailed measured values and timestamps of a record.

Engineering Calculations

Preset Calculation

Calculating the valve preset for a requested flow rate.

Calculation Procedures

Pressure Loss Calculation

Calculating pressure loss on a valve for a given flow and preset.

Available Pressure Calculation

Determining the minimum pressure in a branch after reaching a flow.

Advanced Calculations

Valve Authority Calculation

Calculating the ratio of pressure drop on a valve versus branch pressure.

Quick Records Database

Accessing and browsing previously saved quick recordings.

Device Maintenance

Sintered Filter Replacement

Guide for replacing clogged sintered filters in the pressure inputs.

Battery Replacement

Instructions for replacing batteries and updating the battery type in the app.

Troubleshooting & Safety

Troubleshooting Faults

Common faults, their causes, and recommended repair steps.

Safety and Disposal

Guidelines for safe handling, battery precautions, and device disposal.

Device Specifications

PFM 1000 Specs

Technical specifications including pressure range, errors, operating time, and dimensions.

Danfoss PFM 1000 Specifications

General IconGeneral
Power Supply24 VDC
Ingress ProtectionIP67
Fluid Temperature-40 to 150 °C
Ambient Temperature-20 to 60 °C
Output Signal4-20 mA
CommunicationModbus
Process ConnectionFlanged
Measurement Range0.1 to 10 m/s
Operating Temperature-20 to 60 °C