TP7001
4
GB
GB
Thermostat Features TP7001 TP7001M
Power supply
2 x AA/MN1500/LR6
alkaline batteries
230V ± 15% 50Hz
Memory backup Retained for the life of the product
Factory set calendar clock Automatic summer/winter time change
Switching action of output relay 1 x SPDT, Type 1B
Switch rating of relay contact 3(1) A, 10-230 Volts
Remote sensor inputs
Up to three remote sensors, which can be
set by the installer for remote temperature
sensor, limit sensor, outdoor sensor, window
contact or telephone activated switch
contacts
Rated Impulse Voltage 2.5 kV
Dimensions (mm) 140 wide x 91 high x 28 deep
Ball Pressure Test 75°C
Temperature Range 5-30°C
Design Standard EN 60730-2-7
Control Pollution Situation Degree 2
Time accuracy ± 1 minute per month
Temperature accuracy ±1°C
1.0 Installation Guide
2.0 System Overview
Please Note:
This product should only be installed by a quali ed electrician or
competent heating installer and should be in accordance with the
current edition of the IEEE wiring regulations.