VLT® 5000 Crane
Programming
PNU Parameter Range Factory setting Changes Unit Conversion Data Protection
#
2xx
description
References & Limits
during
operation
index index type level
202 Output speed high
limit
0-5000 RPM 3000 RPM Yes 11 67 6 1
205 Maximum reference 0.001-
100.000
3000 Yes 0 -3 4 1
207 Ramp-up time 1 0.05 - 3600 0.85 sec. Yes 4 -2 7 1
208 Ramp-down time 1 0.05 - 3600 0.85 sec. Yes 4 -2 7 1
211 Jogramptime 0.05 - 3600 0.85 sec. Yes 4 -2 7 1
212 Quick stop
ramp-down time
0.05 - 3600 0.85 sec. Yes 4 -2 7 1
213 Jog speed 0 - 4500 RPM 200 RPM Yes 11 67 6 2
221 Torque limit motor
mode
0.0% - 170% 160 % Yes 24 -1 6 1
222 Torque limit
generator operation
0.0% - 170% 160 % Yes 24 -1 6 1
234 Missing motor phase Enable Yes 0 0 5 1
235 Phase loss monitor Enable No 0 0 5 1
236 Low speed ref.
current
0 - 160% 50% Yes 27 0 5 1
Changes during operation:
"Yes" means that the parameter can be changed,
while the frequency converter is in operation. "No"
means that the frequency converter must be stopped
before a change can be made.
C
onversion index/unit index:
This number refers to a conversion figure to
be used when writing or reading by means of
a frequency converter. Please refer to Serial
Communication in Appendix.
✭
= factory setting. () = display text [] = value for use in communication via serial communication port
MG.50.N4.02 - VLT is a registered Danfoss trademark