WARNING 59, Current limit:
Contact your Danfoss supplier.
WARNING 61, Encoder loss:
Contact your Danfoss supplier.
WARNING 62, Output Frequency at
Maximum Limit:
The output frequency is higher than the value
set in par. 4-19.
ALARM 63, Mechanical Brake Low:
The actual motor current has not exceeded
the “release brake” current within the “Start
delay” time window.
WARNING 64, Voltage Limit:
The load and speed combinations demand a
motor voltage higher than the actual DC link
voltage.
WARNING/ALARM/TRIP 65, Control
Card Overtemperature:
Control card overtemperature: The cut-out
temperature of the control card is 176° F [80°
C].
WARNING 66, Heatsink Temperature
Low:
The heatsink temperature is measured at 32°
F [0° C]. This may indicate that the tempera-
ture sensor is defective, and thus the fan
speed is increased to the maximum if the pow-
er part or control card is very hot.
ALARM 67, Option Configuration has
Changed:
One or more options has either been added or
removed since the last power-down.
ALARM 68, Safe Stop Activated:
Safe Stop has been activated. To resume nor-
mal operation, apply 24 V DC to terminal 37,
then send a reset signal (via bus, digital I/O,
or by pressing [RESET]). For correct and safe
use of the Safe Stop function, follow the rela-
ted information and instructions in the Design
Guide
ALARM 70, Illegal FC Configuration:
Current combination of control board and
power board is illegal.
ALARM 80, Drive Initialized to Default
Value:
Parameter settings are initialized to default
setting after a manual (three-finger) reset.
ALARM 91, Analog Input 54 Wrong Set-
tings:
Switch S202 has to be set in position OFF
(voltage input) when a KTY sensor is connec-
ted to analog input terminal 54.
ALARM 250, New Spare Part:
The power or switch mode power supply has
been exchanged. The adjustable frequency
drive type code must be restored in the EE-
PROM. Select the correct type code in Par
14-23 according to the label on unit. Remem-
ber to select ‘Save to EEPROM’ to complete.
ALARM 251, New Type Code:
The adjustable frequency drive has a new
type code.
VLT
®
Automation Drive FC 300
Instruction Manual High Power
6. Warnings and Alarms
MG.33.U1.22 - VLT
®
is a registered Danfoss trademark.
135
6

Table of Contents

Other manuals for Danfoss VLT FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 300 and is the answer not in the manual?

Danfoss VLT FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals