►►►6. ALARM LIST
ALARM POSSIBLE CAUSE POSSIBLE SOLUTION
FULL + “FULL“ Full or missing tank The alarm is automatically reset by empty-
ing or inserting the tank
ALARM + “Lo t“ Room temperature too
low
Room temperature conditions not suitable
for operation
ALARM + “Prob“ Malfunction of the humid-
ity probe. In any case, the
unit continues to operate
Contact the authorised service centre
ALARM + “Pro2“ Malfunction of the ambi-
ent temperature probe
Contact the authorised service centre
ALARM + “dEFr“
ALARM + “Lotd”
Defrosting thermostat
malfunction
Contact the authorised service centre
ALARM + “HiPS“ High pressure alarm in
the refrigerant circuit

Disconnect the unit from the power supply.
Open the electrical panel and reset the
high pressure switch.
If the alarm persist contact the authorised
service centre
ALARM + “LoPS“ Low pressure alarm in the
refrigerant circuit

Disconnect the unit from the power supply
and riconnect.
If the alarm persist contact the authorised
service centre