Preparation and transport guide, cont.
Position the dehumidifier where there is plenty of air circulation around it, with mini-
mum 60 cm of clearance on the air intake side, and 3 met
ers of clearance on the ex-
Remember also:
• To keep ventilation openings clear of obstruction during operation.
Since the dehumidifiers contain a flammable refrigerant following location requirements
must be
fulfilled:
• The appliance shall be installed, operated and
stored in a room with a floor area larger than
4m
2
. Check if there are any local regulations,
you must comply to, when installing or storing
the appliance.
• The appliance shall be stored in a well-ventilated area, where the room size
corresponds to the room area of 4m
2
.
•
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
Ensure the room to be dehumidified is sealed, and that the machine is not located near
a heat source, such as radiators.
The machine comes complete with a 3.5m power cord, and can be connected to any 230
V, 50 Hz socket with a 10
-16A fuse.
If the plug has 3 pins incl. PE
-connection a plug adapter (accessory – item no. 396249)
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.