Switching on/off
and operating status
The table below shows operation of the on/off function and display texts.
Key
Display
ON constant
INT HYG ON operation controlled by internal hygrostat
INT HYG STOP, if internal hygrostat set point is reached
EXT HYG ON operation controlled by external hygrostat
EXT HYG STOP, if external hygrostat set point is reached
Switch off
The green LED indicates active dehumidification
Operating the heat-
ing element
The integrated 1 kW heating element is activated by setting the
switch behind the water container to setting 1. Switch to O to de-
activate.
Continued on next page
Switch behind water container