EasyManua.ls Logo

darda C2S - Troubleshooting

darda C2S
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7 Troubleshooting
34 OM Hydraulic Stone and Concrete Splitter, Version 1.0 04/2010
Error:
Wedge does not
extend or retract -
Hydraulic aggre-
gate increases
pressure to
50 MPa.
Error:
Wedge moves in
one direction very
slowly.
Error:
Hydraulic aggre-
gate does not
achieve pressure of
50 MPa - Pressure
limitation valve
does not work
7 Troubleshooting
Yes Yes
Yes
No
Yes
No
Clean pressure limi-
tation valve or re-
place O-ring
3390 0130 00.
Portable
aggregate:
Hydraulic hose be-
tween pump and
pressure limitation
valve leaky?
Yes
No No
No
No
Wedge has been
ripped off in the
area of the piston
pin?
(¹ Ch. 4.3).
Spring
3390 0112 00 in the
control valve of the
splitter has bro-
ken?.
Quick-release
coupling does not
have a passageway
- Directly connect
hose.
Replace wedge
(¹ Ch. 6).
Replace spring
3390 0112 00.
Contamination or
defective O-ring
3390 0130 00 in
pressure limitation
valve?
Replace complete
valve seat
3390 0131 00 in
pressure limitation
valve – Pressure
50 MPa?
Tighten and/or
service hose con-
nections.
Replace O-ring
3391 0128 00 –
Pressure 50 MPa?
Replace pump
element
3391 0115 85.
Service or replace
the control valve
3390 0110 82 of the
splitter.
Connect replace-
ment splitter:
Pressure 50 MPa?
No
No
Error:
Hydraulic aggre-
gate does not build
up pressure.