Instruction Manual DS2
25
Remote configuration from host user interface: synoptic table showing the output variation with
respect to the detection analysis mode configuration
Function
Mode
Outputs
Analog
Switching
Serial
Normal
-
Presence detection
-
TEACH-
IN
Get TEACH-IN
from DS2
-
Conditional presence
detection from
TEACH-IN
-
Set TEACH-IN from
User Interface
Conditional presence
detection from
TEACH-IN
TEACH-
IN Mode
Absolute Positioning
Detection
-
Positional detection of
TEACH-IN ref. object
-
Relative Positioning
Detection
Detection of TEACH-
IN reference object
Switching
Output Mode
Normally Opened
-
Current on switching
device during
detection
-
Normally Closed
-
No current on
switching device
during detection
-
Switching
Output Delay
No Delay
-
-
-
0 < T
DELAY
< 200ms
-
Restore from
detection delay =
T
DELAY
-
Output Hold
Enable
It holds
analogue and
serial output
to the higher
detected
value during
enable of
“output
HOLD” input
(pin5 RX
connector on
24Vdc)
-
It holds
analogue and
serial output
to the higher
detected
value during
enable of
“output
HOLD” input
(pin5 RX
connector on
24Vdc)
Disable
Normal operation

Table of Contents