ENTER/EXIT PROGRAMMING MODE
PRODUCT REFERENCE GUIDE
79
USB-OEM Device Usage
The USB-OEM protocol allows for the reader to be identified as one of two different
types of bar code reader. Depending on what other reader you may already have con-
nected to a USB-OEM POS, you may need to change this setting to enable all devices to
communicate.
Options are:
Tabletop Scanner
Handheld Scanner
USB-OEM Interface Options
This setting provides for an interface specific control mechanism.
Options are:
Obey — Obey Scanner Configuration Host Commands
Ignore — Ignore Scanner Configuration Host Commands
NOTE: This feature is not compatible with Multiple Labels Reading in a Vol-
ume.
$CIBUT00
USB-OEM Device Usage = Tabletop Scanner
USB-OEM Device Usage = Handheld Scanner
$CIBUT01
$CIFO101
Interface Options = Obey Scanner Configuration
Host Commands
Interface Options = Ignore Scanner Configuration
Host Commands
$CIFO102