Page #27 background image
Reading Parameters
Quick Reference Guide 17
Reading Parameters
Move the reader toward the target and center the aiming
spot, then pull the trigger to capture and decode the bar-
code. See Using the PowerScan™ PD9330 on page 4 for
more information.
The aiming system will switch off after the acquisition
time.
As you read code symbols, adjust the distance at which
you are holding the reader.
Good Read Green Spot Duration
Successful reading can be signaled by a good read green
spot. Use the bar codes that follow to specify the duration
of the good read pointer beam after a good read.
ENTER/EXIT PROGRAMMING MODE
Disabled

Short (300 ms)
Medium (500 ms)
Long (800 ms