Exit and Save Configuration
16-KEY DK MODEL PARAMETERS
REPEAT TIMEOUT
Repeat Timeout allows the user to program an optional intercode delay (in msec.) between two
codes in a set of codes to be transmitted from scanner to host via Radio interface, when the
scanner is in quantity mode.
NOTE: Qty/Code Send Mode must be set to option 2 (code in CODE field is sent out for a
QTY number of times). See Qty/Code Send Mode on the previous page).
The number of codes depends on the unit inserted via keypad by the user, to cope with different
use cases. A minimum delay of 100 ms will be always present, the delay can be adjusted in
10ms increments.
Read the above code.
Select the length of the delay you want to set by scanning two barcodes (01 – 99) from the
Hex Numeric table in the back of this manual.
Example
: To program Repeat Timeout = 60ms
set Repeat Timeout
Value
Time (ms)
Read
+
06
=
60ms